久久精品国产亚洲欧美成人,国产自国产在线无毒不卡,四虎影视永久在线精品,亚洲中文字幕久爱亚洲伊人

歡迎光臨
手機網(wǎng)站 | 聯(lián)系我們:021-32535039 | 加入收藏
  • ISO16925蒸汽噴射試驗箱

    產(chǎn)品型號: LTA1
    品  牌: 德國
      價格電議,您可以向供應(yīng)商詢價得到該產(chǎn)品價格
    所 在 地: 上海嘉定區(qū)
    更新日期: 2024-12-27
    詳細信息
     品牌:德國  型號:LTA1  加工定制:否  
     類型:耐蒸汽噴射  材質(zhì):不銹鋼  溫度范圍:0-100 ℃ 
     功率:400 W 工作室尺寸:400x500x600 mm 電源:400V  
     適用范圍:汽車零部件涂料  工作室尺寸:400x500x600 mm 電源:400V  
    1 Scope
    This International Standard specifies a test method for the assessment of the resistance of coatings to
    pressure water-jetting. The test method simulates the effects pressure water-jetting has on a coating.
    5 Apparatus and materials
    Ordinary laboratory apparatus, together with the following:
    5.1 Pressure water-jet, consisting of a high-pressure pump and a nozzle.
    A high-pressure pump conveys the water from a storage bin. To avoid influences from variations in
    pressure, it is necessary that the pressure and the volumetric flow rate be adjustable at the nozzle
    described below.
    The water temperature shall be adjustable to ± 2 °C.
    The temperature shall be adjusted in accordance with Annex A. Necessary safety devices on the pressure
    side of the unit, as e.g. pressure relief valve and by-pass valve, shall exist. If the jetting is unsteady, a flow
    calming section may be installed in front of the nozzle. A pulsation of the water jet at the opening of the
    pump is inadmissible. In order to reach a reproducible result, the nozzle shall be solidly mechanically
    fixed and the test specimen shall be secured against slipping. For the adjustment of the volumetric flow
    rate, a nozzle with a jet angle of 25° and a volumetric flow rate of 6 l/min at 2 MPa (20 bar) is required
    (see Annex A).
    The following technical data should be attainable:
    — volumetric flow rate: 8 l/min to 14 l/min
    — pressure: 4 MPa (40 bar) to 13 MPa (130 bar)
    — temperature: 20 °C to 80 °C
    — jetting time: 10 s to 300 s
     

    Figure 1 shows the schematic construction of a pressure water-jet apparatus which is specially built for these tests.
     
    Key
    1 flow calming section
    2 high-pressure valve, height adjustable
    3 test specimen
    4 clamping element  
    5 feed tank
    6 floating valve with filter
    7 water shortage safeguard
    8 heating
    9 base frame, moveable
    10 temperature sensor  
    11 high-pressure pump
    12 by-pass valve  
    13 pressure relief valve
    14 pressure transmitter
    8.1 Introducing the cut or the scribe
    Make sure that the test specimen is securely fastened when introducing the cut or the scribe.
    Introduce both of the cuts or scribes vertically through the coating into the substrate using the cutting
    or scribing tool, as shown in Figure 2. The depth of the cut or scribe into the substrate should be as
    minimal as possible. The length of the first cut or scribe shall be at least 100 mm, if the geometry of the
    part allows that. At an angle, introduce a second cut or scribe with a minimum length of 20 mm. The
    cuts or scribes shall be introduced straight-line at an angle of approximately 30°. An automatic cutting
    or scribing device may be used. Residues of the coating shall be removed from the cut or scribe.
    NOTE The depth of the cut or scribe into the substrate influences the result.
    The cutting or scribing tools should be checked regularly and replaced if necessary.
       Figure 2 — Introducing the cuts or scribes (St Andrew’s cross)

    8.2 Testing
    After inserting the test specimen into the apparatus (e.g. using a spacer block), calibrate the space
    between test specimen and nozzle.
    Operate the pressure water-jetting apparatus at room temperature.
    Three test methods (A, B, or C – see Table 1) are preferred as well as three possible scribing tools (C, L, or
    S – see 5.3). The test method to be applied, the scribing or cutting tool to be used, and the water pressure
    shall be agreed.
    Table 1 — Test methods
     
    Test method Water Temperature
    Impact angle Space between nozzle and sample mm Flow rate
    L/min
    Duration of
    jetting
    A 60±2 90±2 100±1 11.3±0.2 30±1
    B 60±2 90±2 100±1 11.3±0.2 60±1
    C 60±2 90±2 100±1 11.3±0.2 60±1
     
    For jetting, deionized water should be used.
    When using automatic and manual devices, fasten the test specimen so that the water jet impacts as
    shown in Figure 3. The jet impacts in the middle above the point of intersection onto the longer one of both cuts/scribes.

    Figure 3 — Jetting area
    9 Evaluation
    9.1 General
    Damage is recognizable when the coating loosens or flakes, regardless of which coat sustains the damage.
    9.2 Evaluation with pictures to compare
    Carry out the evaluation visually, comparing the specimen with the pictures.
    In the course of the visual evaluation, a characteristic value is laid down by comparing with the
    illustrations in Figures 4 to 9. A characteristic value between 1 and 5 results, depending on the degree
    of damage. No damage corresponds to the characteristic value 0. In addition to the evaluation, if
    applicable, the attribution of the separation from the main separation level or to the respective film
    shall be indicated.
    The result of the visual assessment is indicated in dependence of the applied method, for example:
    — method A: characteristic value A;
    — method B: characteristic value B;
    — method C: characteristic value C.
    NOTE In addition, by measuring the areas of flaking (maximum width, in millimetres, or area, in square
    millimetres), the overall damage can be evaluated. The overall damage is calculated by summing up all damaged
    areas of the test specimen. Even the smallest areas of flaking are measured and calculated, and all areas added to
    the overall damage.

    Figure 5 — Characteristic value 1 for pressure water-jet damage

    Figure 6 — Characteristic value 2 for pressure water-jet damage


    Figure 7 — Characteristic value 3 for pressure water-jet damage

    Figure 8 — Characteristic value 4 for pressure water-jet damage

    Figure 9 — Characteristic value 5 for pressure water-jet damage

     
    Annex A
    (normative)
    Calibration of the test apparatus
    A.1 Apparatus and materials
    Ordinary laboratory apparatus, as well as the following.
    A.1.1 Temperature measuring device, with sensor, capable of measuring to 0,5 °C.
    A.1.2 Balance, weighing to 10 g.
    A.1.3 Time measuring device (stopwatch), capable of measuring ± 0,1 s.
    A.1.4 Container, for the determination of the volumetric flow rate for at least 20 l of water.
    A.1.5 Plastic block, made of polystyrene rigid plastic foam.
    The kind of the polystyrene rigid plastic foam shall be agreed by the interested parties.
    A.1.6 Length measuring device, capable of measuring ± 0,1 mm.
    A.2.4 Calibration of the water jet
    The conditions for the calibration of the jetting are in accordance with method B. For the calibration of
    the jetting, a stainless steel precision flat film extrusion die with a volumetric flow rate of the nozzle of
    6 l/min at 2 MPa (20 bar) and a jet angle 25° is used. This nozzle is required to produce an even liquid
    distribution during the entire jetting.
    When using an automatic pressure-water apparatus, fasten the polystyrene rigid plastic foam in the
    apparatus so that the jet cannot move the block. When using a manual apparatus, fasten the block in a
    similar fixture.
    After jetting, the length and the width of the impact are measured. See Figure A.1.
    The mean length of the impact shall be (73 ± 5) mm and the mean width (8 ± 1) mm on average.


    Figure A.1 — Measures of the washed-out areas in the polystyrene rigid plastic foam
    蒸汽噴射試驗機滿足測試規(guī)范汽車廠家:寶馬、奔馳、通用、大眾、福特、沃爾沃等規(guī)范(AA-0136、DIN 55662、ISO16925DBL 7381,GM9531P、PV1503、VOLVO STD 423-0015,VOLVO VCS 1029 54719、FLTM BO 160-04、MS210-07PSA D23 5376,Renault D25 2018/-A-2001 ,GMW16745-2012方法B,TPJLR-52.561-2009 